HAZARDOUS LOCATION AND EXPLOSION PROOF AIR CIRCULATORS
Provide both spot and general cooling in atmospheres containing flammable of explosive vapors, gases, or dusts as defined under articles 500 of the national electric code (NEC)
Totally enclosed fan cooled (TEFC), single speed hazardous location, capacitor start, ball bearing motor with automatic reset thermal protection, UL listed conduit box supplied with motor
Motors only are UL Listed (E62643) for Class I, Division I, Group D, and Class II, Division I , Groups E, F, and G hazardous locations
Zinc plated steel guards comply with OSHA standard 1910.212,1/2" Max. opening requirenemets
Spark-resistant cast aluminum propeller
Supplied with galvanized steel wall bracket for mounting to wall or post
Mounting brackets allow adjustment for multi-directional air flow
Secondary support cable included for overhead mounting
Fan not appropriate for use where paint residue can accumulate on motor or blade
24" Unit extends 23-7/16" from wall; 30" Unit extends 25-1/8" from wall
Propeller DIA. (IN.) CMF Air Velocity @ 20'(FPM) HP RPM
24 5486 520 1/4 1140
Watts Operating AMPS Volts Motor Type Velocity Profile
353 6.0/2.9 115/230 CSIR G
Propeller DIA. (IN.) CMF Air Velocity @ 20'(FPM) HP RPM
30 10937 520 3/4 1140
Watts Operating AMPS Volts Motor Type Velocity Profile
701 7.0/3.5 115/230 CSCR H